From Wellman Laboratories of Photomedicine (G.J.T., K.H.S., C.R.K., M.S., B.E.B.), Department of Pathology (G.J.T., S.L.H., H.T.A.), Cardiology Division (H.Y., I.-K.J.), and Department of Radiology (E.F.H.), Massachusetts General Hospital and Harvard Medical School, Boston, Mass; and First Department of Internal Medicine (H.Y.), Kinki University School of Medicine, Osakasayama, Osaka, Japan.
| Abstract |
|---|
| Top Abstract Introduction Methods Results Discussion References |
|---|
Background— Macrophage degradation of fibrous cap matrix is an important contributor to atherosclerotic plaque instability. An imaging technology capable of identifying macrophages in patients could provide valuable information for assessing plaque vulnerability. Optical coherence tomography (OCT) is a new intravascular imaging modality that allows cross-sectional imaging of tissue with a resolution of
Methods and Results— OCT images of 26 lipid-rich atherosclerotic arterial segments obtained at autopsy were correlated with histology. Cap macrophage density was quantified morphometrically by immunoperoxidase staining with CD68 and smooth muscle actin and compared with the standard deviation of the OCT signal intensity at corresponding locations. There was a high degree of positive correlation between OCT and histological measurements of fibrous cap macrophage density (r=0.84, P<0.0001) and a negative correlation between OCT and histological measurements of smooth muscle actin density (r=-0.56, P<0.005). A range of OCT signal standard deviation thresholds (6.15% to 6.35%) yielded 100% sensitivity and specificity for identifying caps containing >10% CD68 staining.
Conclusions— The high contrast and resolution of OCT enables the quantification of macrophages within fibrous caps. The unique capabilities of OCT for fibrous cap characterization suggest that this technology may be well suited for identifying vulnerable plaques in patients.
Key Words: atherosclerosis catheters imaging tomography plaque
| Introduction |
|---|
| Top Abstract Introduction Methods Results Discussion References |
|---|
Cellularity of fibrous caps of atherosclerotic plaque, manifested by the infiltration of macrophages (average size, 20 to 50 µm), is thought to weaken the structural integrity of the cap1–3 and predispose plaques to rupture. Macrophages and other plaque-related cells produce proteolytic enzymes, such as matrix metalloproteinases, that digest extracellular matrix and compromise the integrity of the fibrous cap.4–7 Activated macrophages are strongly colocalized with local thrombi in patients who have died of acute myocardial infarction7 and are more frequently demonstrated in coronary artery specimens obtained from patients suffering from acute coronary syndromes compared with patients with stable angina.3 This evidence suggests that an imaging technology capable of identifying macrophages in patients would provide valuable information for assessing the likelihood of plaque rupture.
Intravascular optical coherence tomography (OCT) is a recently developed optical imaging technique that provides high-resolution, cross-sectional images of tissue in situ.8,9 The resolution of OCT,
10 µm, is appropriate for measuring the cap thickness (<100 µm) that is characteristic of a vulnerable plaque. Previous studies have demonstrated the visualization of microstructural features in atherosclerotic plaques with OCT.10–12 Results from intracoronary OCT, recently performed in patients, have shown an improved capability for characterizing plaque microstructure compared with intravascular ultrasound.12,13 To date, however, the use of OCT for characterizing the cellular constituents of fibrous caps has not been investigated. The purpose of this study was to evaluate the potential of OCT for identifying macrophages in fibrous caps of atherosclerotic plaques.
| Methods |
|---|
| Top Abstract Introduction Methods Results Discussion References |
|---|
Specimens
A total of 26 lipid-rich atherosclerotic arterial plaques (19 aortas and 7 carotid bulbs) were obtained from 17 randomly selected cadavers (10 male and 7 female, mean age 73.2±15.2 years) to quantify macrophage content. The harvested arteries were stored immediately in PBS at 4°C. The time between death and OCT imaging did not exceed 72 hours. The Institutional Review Board at the Massachusetts General Hospital approved the experimental protocol.
OCT Imaging Studies
The OCT system used in the present study has been previously described.8,9,14 OCT images were acquired at 4 frames per second (500 angular pixelsx250 radial pixels), displayed with an inverse gray-scale lookup table, and digitally archived. The optical source used in this experiment had a center wavelength of 1310 nm and a bandwidth of 70 nm, providing an axial resolution of
10 µm in tissue. The transverse resolution, determined by the spot size of the sample arm beam, was 25 µm.
Before OCT imaging, arteries were warmed to 37°C in PBS. Each carotid bulb and aorta was opened and imaged with the luminal surface exposed. The position of the interrogating beam on the tissue was monitored by a visible light aiming beam (laser diode, 635 nm) that was coincident with the infrared beam. Precise registration of OCT and histology was accomplished by using a 26-gauge needle to apply ink marks (Triangle Biomedical Sciences) at the imaging site, such that each OCT image and corresponding histological section contained visually recognizable reference points.
Staining
After imaging, the tissue was processed in a routine fashion. Arterial segments were fixed in 10% formalin (Fisher Scientific) for at least 48 hours. Arteries with substantial calcification were decalcified (Cal-EX, Fisher Scientific) before standard paraffin embedding. Four-micron sections were cut at the marked imaging sites and stained with H&E and Masson’s trichrome. To visualize the presence of macrophages and smooth muscle cells, a mouse anti-human CD68 monoclonal antibody and
-actin monoclonal antibody (Dako Corporation) were used, respectively. Immunohistochemical detection of the preferred epitopes was performed according to the indirect horseradish peroxidase technique. After blocking with horse serum, the tissue was incubated with primary antibodies followed by horse anti-mouse secondary antibody and streptavidin with peroxidase (BioGenex) for anti–smooth muscle actin or avidin-biotin horseradish peroxidase complex (Dako Corporation) for anti-CD68. Slides were developed with 3-amino-9-ethyl-carbazole (Sigma) and counterstained with Gill’s hematoxylin (Fisher Scientific). All slides were digitized for histomorphometric analysis (Insight Camera, Diagnostic Instruments).
Morphometric Analysis
Macrophage Content Measurement
With the use of both digitized histology and OCT, measurements of macrophage density were obtained using a 500x125-µm (lateral x axial) region of interest (ROI), located in the center of the plaque. For caps having a thickness <125 µm, the depth of the ROI was matched to the cap thickness. In this study, tissue present within the ROI did not demonstrate histological evidence of either calcium or cholesterol crystals.
|
OCT measures the intensity of light returning from within a sample. Samples having a higher heterogeneity of optical index of refraction exhibit stronger optical scattering and therefore a stronger OCT signal. If the characteristic size scale of the index of refraction heterogeneity is larger than the resolution, then the OCT signal will have a larger variance. Previous research conducted to measure the optical properties of human tissue has shown that the refractive index of lipid and collagen is significantly different.15 These results suggest that caps containing macrophages should have multiple strong back reflections, resulting in a relatively high OCT signal variance. With standard image processing methods,16 the variance,
2, within the ROI of an OCT image can be represented by the following:
|
where N is the number of pixels in the ROI, ROIwidth is the width of the ROI, ROIheight is the height of the ROI, S(x,y) is the OCT signal as a function of x and y locations within the ROI, and
is the average OCT signal within the ROI.
OCT images contain tissue back-reflection information that spans a large dynamic range (100 dB or 10 orders of magnitude). The dynamic range of OCT is too high to be displayed on a standard monitor, which may have a dynamic range of only 2 to 3 orders of magnitude. As a result, the signal range of most OCT images is compressed by taking the base 10 logarithm of the OCT image before display. Although taking the logarithm of the OCT image data enables convenient image display, compression of the data range in this manner diminishes image contrast. In the present study, we investigated the capabilities of both the raw (linear) OCT data and the logarithm of the OCT data for quantifying macrophage content within fibrous caps.
Before computing the image standard deviation, the OCT data within the ROI were preprocessed according to the following steps. First, the mean background noise level was subtracted, and then median filtering16 with a 3x3 square kernel was performed to remove speckle noise (IPLab Spectrum 3.1, Scanalytics). After preprocessing,
within the ROI was calculated and tabulated for each specimen. To correct the data for variations in OCT system settings,
was normalized by the maximum and minimum OCT signal present in the OCT image, as follows:
|
|
where NSD is the normalized standard deviation of the OCT signal, Smax is the maximum OCT image value, and Smin is the minimum OCT image value.
The area percentage of CD68 and smooth muscle actin staining was quantified (at x100 magnification) with automatic bimodal color segmentation16 within the corresponding ROIs of the digitized immunohistochemically stained slides (IPLab Spectrum 3.1, Scanalytics). The NSD within each cap was then compared with immunohistochemical staining from slides obtained from corresponding locations.
Cap Thickness Measurement
Both digitized histology and OCT measurements of cap thickness were taken at the center of each plaque (IPLab Spectrum 3.1, Scanalytics). A pathologist, blinded to the OCT results, morphometrically measured the fibrous cap thicknesses from digitized trichrome-stained slides. A total of 5 measurements by histology were obtained from each specimen. The maximum and minimum measurements were excluded, and the average of the remaining 3 measurements was used to comprise the data set.
Statistics
OCT measurements of macrophage and smooth muscle density were compared with histological measurements using linear regression. Because of the potential confounding association of OCT NSD with cap thickness, a partial correlation between the raw OCT NSD and CD68 percent area and smooth muscle actin percent area, controlling for histological measurements of cap thickness, was also calculated. In addition, after retrospective application of an NSD threshold, the accuracy of OCT for identifying caps with >10% CD68 staining was determined. All continuous variables are expressed as mean±SD. P<0.05 was considered statistically significant.
| Results |
|---|
| Top Abstract Introduction Methods Results Discussion References |
|---|
Macrophage Density
shows representative OCT and histological images for plaques with low and high macrophage content. As seen in this figure, the OCT signal within the cap is relatively homogeneous for low macrophage density, whereas for high macrophage content, the OCT image of the cap is heterogeneous with punctate, highly reflecting regions. The relationship between macrophage density determined by immunohistochemistry and the NSD measured by OCT is depicted in for both the raw and base 10 logarithm OCT data. For the raw OCT data, a correlation of r=0.84 (P<0.0001) was found between OCT NSD and CD68 percent staining, whereas for the base 10 logarithm OCT data, a correlation of r=0.47 (P<0.05) was found between OCT NSD and CD68 percent staining. The partial correlation of raw OCT NSD and CD68 percent staining, controlling for cap thickness, was r=0.80 (P<0.0001), indicating that OCT measurement of macrophage density is independent of cap thickness.
|
|
Morphometric evaluation of 26 slides stained with CD68 showed 9 caps with a CD68 area >10% and 17 caps with a CD68 area <10%. Receiver operating characteristic (ROC) curves for the raw and base 10 logarithm OCT signal NSDs are depicted in . For the raw OCT signal NSD, a range of NSDs (6.15% to 6.35%) demonstrated 100% sensitivity and specificity (
value 1.0) for differentiating caps containing >10% CD68 staining. For the base 10 logarithm OCT signal, NSD values ranging from 7.65% to 7.75% provided 70% sensitivity and 75% specificity (
value 0.44) for identifying caps containing >10% CD68 staining. A comparison of the OCT NSD and CD68 staining is summarized in the
|
|
Smooth Muscle Cell Density
A negative correlation was found between CD68 and smooth muscle actin percent area staining (r=-0.44, P<0.05). In turn, a statistically significant negative relationship between smooth muscle cell density determined by immunohistochemistry and OCT NSD was observed for both the raw and base 10 logarithm OCT data. For the raw OCT data, a correlation of r=-0.56 (P<0.005) was found between OCT NSD and smooth muscle actin–positive percent staining, whereas for the base 10 logarithm OCT data, a correlation of r=-0.32 (P=0.12) was found between OCT NSD and smooth muscle actin–positive percent staining. The partial correlation of the raw OCT NSD and smooth muscle actin percent area staining, controlling for cap thickness, was r=-0.38 (P<0.05).
| Discussion |
|---|
| Top Abstract Introduction Methods Results Discussion References |
|---|
Although many new approaches under investigation for plaque characterization show great promise, none provide direct evidence of macrophage presence. This study demonstrates that OCT is capable of visualizing macrophages and quantifying cap macrophage content. Because the OCT signal increases with the number of refractive index mismatches in tissue, caps containing macrophages should have multiple strong back reflections. A simple computational analysis of ROIs within OCT images of fibrous caps (NSD) was developed to test this hypothesis. When validated against immunohistochemistry, this parameter demonstrated a high degree of correlation with CD68 staining at corresponding locations (r=0.84 for raw OCT data NSD).
Although little is known about the precise relationship between cap macrophage density and plaque vulnerability, studies have shown that plaques with a macrophage content in the range of 10% to 20% are more likely to be associated with unstable angina and non–Q-wave myocardial infarction.3 As a result, we selected 10% CD68 area as a cutoff for high macrophage content. Using the ROC to select an appropriate NSD threshold, we found that OCT was capable of accurately distinguishing fibrous caps with low macrophage content from fibrous caps with high macrophage content (100% sensitivity and specificity for raw OCT data NSD).
Studies have shown that macrophages are more abundant than smooth muscle cells in the plaques of patients with unstable angina.7,17 In the present study, we found an inverse correlation between CD68 and smooth muscle actin staining from corresponding locations within plaque caps (r=-0.44, P<0.05). The negative correlation between the raw OCT data NSD and smooth muscle actin staining (r=-0.56, P<0.005) may in part reflect the inverse relationship between macrophages and smooth muscle cells in our data. Nevertheless, it seems that the OCT NSD is specific for macrophage content, as opposed to being a more general metric of increased cellular density.
In the present study, both the raw OCT signal and the logarithm of the OCT signal were processed and compared with CD68 immunohistochemical positivity. Although the logarithm of the OCT signal provides an increased dynamic range for image display, it also apparently decreases the contrast between macrophages and surrounding matrixOn the basis of our results here, we recommend that image quantification for determination of macrophage content be performed on the raw OCT signal.
Alternative Methods for Identifying Inflammation in Atherosclerotic Plaques
Diffuse near-infrared (NIR) reflectance spectroscopy is a quantitative approach that uses the spectrum of light scattered from within the vessel wall.18 A recent study using cadaver specimens has demonstrated that chemometric analysis of the NIR spectrum may allow identification of plaques containing abundant inflammatory cells.18 On the basis of the hypothesis that local inflammation within vulnerable plaques may lead to local elevations in temperature, studies have recently been performed using a temperature-sensing catheter. Experiments conducted in patients have indicated that both temperature heterogeneity and the temperature difference between atherosclerotic plaque and healthy vessel walls increase with disease severity.19–21 Both NIR spectroscopy and thermography seem promising for assessing inflammation within plaques, but these diagnostic techniques are not specific for macrophages and may need to be combined with another imaging modality to precisely determine whether the inflammatory cells are confined to the fibrous cap or are present throughout the plaque. Recently, ultrasmall superparamagnetic particles of iron oxide have been proposed for delineation of inflammatory changes accompanying atherosclerotic disease.22 The limited resolution of magnetic resonance imaging, however, renders the localization of macrophages within thin fibrous cap and plaque shoulders difficult.
Study Limitations
Because cadaver specimens were used in this study, minor tissue changes may have occurred postmortem. The effect of specimen degradation over a period of 72 hours (the maximum time between death and OCT imaging in this study) on arterial optical properties is not known. However, a recent feasibility study, performed in patients, has shown that OCT images of coronary plaques obtained in vivo demonstrate similar features to those identified in this work12. Therefore, it is likely that the OCT data analysis algorithms described here will also be applicable to intracoronary OCT images obtained from patients.
|
Because the resolution of the OCT system used in the present study was
10 µm, clear visualization of individual mononuclear macrophages was not possible. As a result, the NSD computed by the image-processing algorithm represents the reflectivity differences between collections of macrophages and surrounding cap matrix. Furthermore, sizes of macrophages vary widely, and the preprocessing step used to reduce speckle noise may remove information related to macrophage content. Future technology development to increase the resolution of OCT23–25 will reduce the dependence of quantitative macrophage determination on noise and could potentially enable the identification and tracking of individual macrophages within fibrous caps.
Selection of the location of macrophage density measurement in both OCT and histology may introduce a bias that could potentially affect the results of this study. To minimize this potential bias, we obtained measurements only at the center of each plaque. Registration of OCT and histology was accomplished by applying ink marks to the vessels at the imaging site. Because the outer diameter of the needle used to apply the ink marks was 450 µm (26 gauge), we estimate that the registration precision in this study was
500 µm. Because macrophage density may vary as a function of measurement location, our results may be affected by errors in registration between OCT images and corresponding histological sections. This limitation is present in all correlative studies of this type and must be considered when interpreting the results.
Conclusion
In conclusion, our results show that OCT is capable of accurately evaluating cap macrophage content. These findings are significant, because macrophage density is thought to be a major contributor in determining fibrous cap integrity. The ability of this imaging modality to quantify cap macrophage density is complementary to the high-resolution, cross-sectional visualization of plaque morphology provided by OCT. The simplicity of the image-processing algorithm used for macrophage evaluation should permit real-time superposition of this information during clinical imaging. These unique capabilities of OCT suggest that this technology may provide researchers and clinicians with a valuable tool for understanding the contributions of these inflammatory cells to plaque progression and rupture in patients.
| Acknowledgments |
|---|
This study was funded in part by the Center for Integration of Medicine and Innovative Technology (development of the imaging system platform) and the Guidant Corporation.
Received July 18, 2002; accepted September 10, 2002.
| References |
|---|
| Top Abstract Introduction Methods Results Discussion References |
|---|
- Fuster V, Lewis A. Conner Memorial Lecture. Mechanisms leading to myocardial infarction: insights from studies of vascular biology. Circulation. 1994; 90: 2126–2146.
- Lendon CL, Davies MJ, Born GV, et al. Atherosclerotic plaque caps are locally weakened when macrophages density is increased. Atherosclerosis. 1991; 87: 87–90.
- Moreno PR, Falk E, Palacios IF, et al. Macrophage infiltration in acute coronary syndromes: implications for plaque rupture. Circulation. 1994; 90: 775–778.
- Galis ZS, Sukhova GK, Kranzhofer R, et al. Macrophage foam cells from experimental atheroma constitutively produce matrix-degrading proteinases. Proc Natl Acad Sci U S A. 1995; 92: 402–406.
- Lee RT, Schoen FJ, Loree HM, et al. Circumferential stress and matrix metalloproteinase 1 in human coronary atherosclerosis: implications for plaque rupture. Arterioscler Thromb Vasc Biol. 1996; 16: 1070–1073.
- Davies MJ, Richardson PD, Woolf N, et al. Risk of thrombosis in human atherosclerotic plaques: role of extracellular lipid, macrophage, and smooth muscle cell content. Br Heart J. 1993; 69: 377–381.
- van der Wal AC, Becker AE, van der Loos CM, et al. Site of intimal rupture or erosion of thrombosed coronary atherosclerotic plaques is characterized by an inflammatory process irrespective of the dominant plaque morphology. Circulation. 1994; 89: 36–44.
- Huang D, Swanson EA, Lin CP, et al. Optical coherence tomography. Science. 1991; 254: 1178–1181.
- Tearney GJ, Brezinski ME, Bouma BE, et al. In vivo endoscopic optical biopsy with optical coherence tomography. Science. 1997; 276: 2037–2039.
- Brezinski ME, Tearney GJ, Bouma BE, et al. Imaging of coronary artery microstructure (in vitro) with optical coherence tomography. Am J Cardiol. 1996; 77: 92–93.
- Brezinski ME, Tearney GJ, Bouma BE, et al. Optical coherence tomography for optical biopsy: properties and demonstration of vascular pathology. Circulation. 1996; 93: 1206–1213.
- Jang IK, Bouma BE, Kang DH, et al. Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound. J Am Coll Cardiol. 2002; 39: 604–609.
- Jang IK, Tearney G, Bouma B. Visualization of tissue prolapse between coronary stent struts by optical coherence tomography: comparison with intravascular ultrasound. Circulation. 2001; 104: 2754.
- Bouma BE, Tearney GJ. Power-efficient nonreciprocal interferometer and linear-scanning fiber-optic catheter for optical coherence tomography. Opt Lett. 1999; 24: 531–533.
- Tearney GJ, Brezinski ME, Southern JF, et al. Determination of the refractive index of highly scattering human tissue by optical coherence tomography. Opt Lett. 1995; 20: 2258–2260.
- Pratt WK. Digital Image Processing. Second ed. New York: John Wiley and Sons; 1991.
- Bauriedel G, Hutter R, Welsch U, et al. Role of smooth muscle death in advanced coronary primary lesions: implications for plaque instability. Cardiovasc Res. 1999; 41: 480–488.
- Moreno P, Lodder R, Purushothaman K, et al. Detection of lipid pool, thin fibrous cap, and inflammatory cells in human aortic atherosclerotic plaques by near-infrared spectroscopy. Circulation. 2002; 105: 923–927.
- Casscells W, Hathorn B, David M, et al. Thermal detection of cellular infiltrates in living atherosclerotic plaques: possible implications for plaque rupture and thrombosis. Lancet. 1996; 347: 1447–1451.
- Stefanadis C, Toutouzas K, Tsiamis E, et al. Increased local temperature in human coronary atherosclerotic plaques: an independent predictor of clinical outcome in patients undergoing a percutaneous coronary intervention. J Am Coll Cardiol. 2001; 37: 1277–1283.
- Stefanadis C, Diamantopoulos L, Vlachopoulos C, et al. Thermal heterogeneity within human atherosclerotic coronary arteries detected in vivo: a new method of detection by application of a special thermography catheter. Circulation. 1999; 99: 1965–1971.
- Ruehm SG, Corot C, Vogt P, et al. Magnetic resonance imaging of atherosclerotic plaque with ultrasmall superparamagnetic particles of iron oxide in hyperlipidemic rabbits. Circulation. 2001; 103: 415–1422.
- Hartl I, Li XD, Chudoba C, et al. Ultrahigh-resolution optical coherence tomography using continuum generation in an air-silica microstructure optical fiber. Opt Lett. 2001; 26: 608–610.
- Bouma BE, Tearney GJ, Bilinski IP, et al. Self-phase-modulated Kerr-lens mode-locked Cr:forsterite laser source for optical coherence tomography. Opt Lett. 1996; 21: 1839–1841.
- Povazay B, Bizheva K, Unterhuber A, et al. Submicrometer axial resolution optical coherence tomography. Opt Lett. 2002; 27: 1800–1802.
Volumetric Quantification of Global and Regional Left Ventricular Function From Real-Time Three-Dimensional Echocardiographic Images
Volumetric Quantification of Global and Regional Left Ventricular Function From Real-Time Three-Dimensional Echocardiographic Images
Quantification of Distention in CT Colonography: Development and Validation of Three Computer Algorithms
Phase-Contrast Magnetic Resonance Flow Quantification in Renal ArteriesComparison With 133Xenon Washout Measurements
Probe-Independent and Direct Quantification of Insulin mRNA and Growth Hormone mRNA in Enriched Cell Preparations
Adenoviral Gene Transfer of Fortilin Attenuates Neointima Formation Through Suppression of Vascular Smooth Muscle Cell Proliferation and Migration
Aspirin Alters the Cardioprotective Effects of the Factor XIII Val34Leu Polymorphism
Atorvastatin Reduces the Ability of Clopidogrel to Inhibit Platelet Aggregation
Contemporary Management of Patent Foramen Ovale
Current Use of Unopposed Estrogen and Estrogen Plus Progestin and the Risk of Acute Myocardial Infarction Among Women With Diabetes